Tabs
 
Specifications - MX-BPM
 Electrical
  Beam Intensity Range  >75dB
  Input Signals  +5dBm to -70dBm in to 50 ohms
  Operating Frequency  60 - 800MHz
  Noise (rms)  <2mV [0 to 1kHz] in ±10V @ -5dBm
 <5mV [0 to 1kHz] in ±10V @ -35dBm
 <50mV [0 to 1kHz] in ±10V @ -60dBm
  Linearity Error  On center: <5mV [+5dBm to -35dBm]
 2mm off center: <20mV [+5dBm to -35dBm]
  Sensitivity  Programmable, but 1V/mm is recommended
  Gain, X & Y  Factory set as required by vacuum chamber used
  Sampling Rate  2,000 per second with internal clock
 up to 10,000 per second when using an external clock
  Local Oscillator  Factory set
  Intermediate Frequency  10.7MHz or 21.4MHz, depending on ƒrev
  Outputs  X: ±10V, A-B-C+D or D-B
 Y: ±10V, A+B-C-D or A-C
 Sum: A+B+C+D or 3V
 A, B, C and D: >0 to <+10V
  Single Button Output  Output on "X": >0 to <+10V
  Button Address  Two address lines, TTL
  Single Button Sampling  Enable and Reset, TTL
  Fast Gate Mode  Enables TTL command
  Fast Gate  NIM (50 ohms, negative pulse, -16mA)
  PLL Lock Indicator  Front Panel LED
  Power Supply  +15V @ <200mA, -15V @ <40mA
 Connectors
  Rear Connector  DIN41612-M, 24 + 8 co-axial (4 used, size 1.0/2.3)
  Front Panel Connectors  DB9, female for test signals
 SMA, for optional IF output
 Rack Mounting Enclosure
  Type  19" Rack Mount Chassis, 3U, RF Shielded
  Capacity  16 BPM Euromodules
  Power Supply  ±15V output, 100 to 240VAC, 50/60Hz input
  Includes  One BPM test station
 Rear panel with SMA input for button signal inputs
 DB9 male connector for external command input
 DB15 female oupput connector per installed station
 