Bergoz Current Transducer, DC/AC, IPCT 
Tabs
 
Specifications - IPCT
   Mechanical Specifications / Other
  Inside Diameter  69mm (2.716in)
  Dimensions  112mm (4.410in) W x 51mm (2.000in) D x 200mm (7.874in) H
  Weight  0.5kg (1.1lbs)
  Connector  DB9 male on front panel
 Electrical Specifications
  Full scale range  Any value from ±1 mA to ±5000 mA (5A), factory preset
  Overrange  120% full scale permanently
  Saturation  > 120% full scale
  Damage level  DC: unlimited, sensor saturates at approximately 1.1 x fs
  Voltage isolation  5 kV current conductor to ground, user may add additional insulation
  Resolution  < 10 μA rms (1sec integration)
  Linearity error  < 0.1% fs
  Absolute accuracy  +- 0.5% fs
  Calibration  Internal 10 turn winding, <1A max
  Ripple  7 kHz and even harmonics, amplitude depends on range
  Bandwidth  DC up to 4 kHz, depending on range
  Response Time  For 100mA fs: 50% < 130µs, 90% <250µs. Depends on fs range.
  Output  ±10 V bipolar, buffered (20 mA max.) withstands permanent short circuit
  Power Supply  ±12V to ±15V, 100mA (see Note 1 below)
  Temperature Zero Drift  ± 5µA/°C
  Temperature Sensitivity Drift  <± 100ppm/°C
  Operating Temperature  - 25°C to 60°C
  Storage Temperature
  (to avoid damage)
 - 40°C to 100°C
  Zero adjust  20-turn front-panel potentiometer. Adjust after power on.
  Stabilization after overload  10 ms max
  Magnetic field sensitivity  50 μA/Gauss typ.

Note 1: The zero offset should be adjusted with the dc power applied and the primary current circuit open at zero current. DC power should not be removed with primary current flowing to avoid offset shift and possible damage to the IPCT.

 Drawings
IPCT Dimensions
Excitation Chart

 Specifications are subject to change without notice.


 Last updated on: 27 April, 2007
   
 