Danfysik Current Transducers, 860 
Tabs
 
Specifications - 860R-600, 860R-2000 & 860R-5000
The 860R-5000 is no longer in production see Discontinued Products.
 Electrical
  860R-600 860R-2000 860R-5000
  Primary Current
40 to 600A
in 40A steps
125 to 2,000A
in 125A steps
5,000A
  Polarity
Bipolar
  Output Voltage (maximum)
0 to ± 10V
  Output Current (maximum)
5mA
  Overload Capacity
   Normal Operation
   Basic Function Maintained
   Fault

100%
115%
500% (0.1s)

100%
115%
300% (0.1s)
  Calibration (Absolute @25°C)
< 50ppm (1)
  Linearity
< 5ppm
< 6ppm
  DC Accuracy
   Initial
     Vs. Temperature
     Vs. Time
   Offset
     Initial
     Vs. Temperature
     Vs. Time


< 1ppm/°C
< 1ppm/month

< 5ppm
< 0.5ppm/°C
< 1ppm/month

< 5ppm
< 0.5ppm/°C
< 1ppm/month
  Output Noise (rms)
   DC-10Hz
   DC-10kHz
   DC-50kHz

< 0.1ppm
< 2ppm
< 5ppm

< 0.1ppm
< 5ppm
< 8ppm

< 0.1ppm
< 4ppm
< 10ppm
  Feedback Noise (rms)
   DC-50kHz (measured on
   the primary current cable - 
   one turn)
< 2µV
< 10µV < 25µV
  Slew Rate
   (Output Voltage, 10-90%)
> 200V/ms
> 100V/ms
> 50V/ms
  Bandwidth
   (- 3 dB, small signal, 0.5%)
40 to 100A range: DC to 50kHz.
100 to 600A range: DC to 300kHz
125 to 250A range: DC to 30kHz
250 to 2000A range: DC to 50kHz
DC to 30kHz
  Test Voltage
    (Transducer Head)
5kVAC (rms)
  Operating Temperature
   Control
   Head

10 to 40°C
0 to 60°C
0 to 50°C
  Input power requirement
115 or 230 VAC, 50/60Hz, 50VA
  Busbar Free Zone
   (from center)
R > 70mm
  Conductor Position Sensitivity
< 0.3 ppm/mm
  Magnetic Field Coeff.
   Axial
   Radial

< 2 ppm/mT
< 5 ppm/mT

< 0.1 ppm/mT
< 1 ppm/mT
  Cable Length
   Standard
   Max

2.5m
30m (with reduced bandwidth)

10m
 Mechanical  
  Dimensions
   Control (W x H x D)
   Weight

   Head
   Hole Diameter
   Weight

483 x 88 x 300
5.1kg

127 x 131 x 48
26
1.1kg

483 x 88 x 300
5.1kg

160 x 197 x 55
50
3.3kg

483 x 133 x 420
14kg

250 x 250 x 152
60
12kg
  Connectors  
   Front
    Test

 2.0mm pin jacks, shorting
   Rear
    Power

    Transducer
    Fine Control Input
    Status/Interlock Output
    Analog Output

 Schaff Power Line Filter with Voltage Select
 and Fuse Holder. P/N FN 376-2
 D25, male
 D9, male
 D15, male
 D9, female

 Notes:
  (1) Calibration accuracy of 25 ppm is available on special order and at an
       additional cost.

 All ppm figures refer to primary current (DC or peak). For programmable current transducers refer to highest acheivable primary current, example given 860R-2000 programmed to 1125A the ppm figure refers to the 2000A that is achievable.
 All dimensions are in mm.
 Specifications are subject to change without notice.
    
 
Site Map Search Powered byGoogle Legal Information Privacy Policy GMW Associates, Inc.
   
Tel: + 650-802-8292    Fax: + 650-802-8298
955 Industrial Road, San Carlos, CA 94070, USA