Specifications
- 862R
|
| Electrical
|
| Primary
Current |
7.5,
10, 16, 20, & 24kA |
| Polarity |
Bipolar
|
| Output
Voltage (maximum) |
0
to ± 10V (1)
|
| Output
Current (maximum) |
5mA
|
Overload
Capacity
Normal Operation
Basic Function Maintained
Fault |
100%
115%
300% (0.1s)
|
| Calibration
(Absolute @25°C) |
<
50ppm (2)
|
| Linearity |
<
5ppm
|
DC
Accuracy
Initial
Vs. Temperature (typ)
Vs. Temperature (max)
Vs. Time
Offset
Initial
Vs. Temperature
Vs. Time |
< 0.5ppm/°C
< 1ppm/°C
< 1ppm/month
|
|
< 5ppm
< 0.5ppm/°C
< 1ppm/month
|
Output
Noise (rms)
DC-10Hz
DC-1kHz
DC-10kHz
DC-50kHz |
< 0.1ppm
< 0.5ppm
< 2ppm
< 5ppm |
Feedback
Noise (rms)
DC-100kHz (measured on the
primary current cable - one turn) |
<
2µV
|
Slew
Rate
(Output Voltage, 10-90%) |
> 10 x I(fs)/ms |
Bandwidth
(- 3 dB, small signal, 0.5%) |
DC
to 30kHz
|
Test
Voltage
(Transducer Head) |
10kVAC
(rms)
|
Operating
Temperature
Control
Head |
10 to 40°C
|
|
0
to 50°C
|
| Input
power requirement |
115
or 230 VAC, 50/60Hz, 150-250VA
|
Busbar
Free Zone
(from center) |
R
> 70mm
|
| Conductor
Position Sensitivity |
<
0.3 ppm/mm
|
Magnetic
Field Coeff.
Axial
Radial |
< 2 ppm/mT
< 5 ppm/mT
|
Cable
Length
Standard
Max |
5m
30m (with reduced bandwidth)
|
| Mechanical
|
Dimensions
Control (W x H x D)
Weight
Head
|
483 x 222 x 420
14kg
Please refer to the transducer
head drawings for dimensions |
| Connectors
|
Front
Test |
2.0mm pin jacks, shorting |
Rear
Power
Transducer
Fine Control Input
Status/Interlock
Output
Analog Output |
Schaff Power Line Filter with Voltage
Select and Fuse Holder. P/N FN 376-2
D25, male
D9, male
D15, male
D9, female |
|
|
Notes:
(1) Full scale voltage outputs
of less than ±10V are available on special order
and at an
additional cost.
(2) Calibration accuracy of 25
ppm is available on special order and at an
additional
cost.
All ppm figures refer to full scale output
All dimensions are in mm.
Specifications are subject to change without notice.
|