| 3474
ELECTROMAGNET SYSTEM WITH FIELD REVERSAL |
APPLICATIONS:
This Electromagnet System is suitable for applications
requiring high fields and field reversal, such as
B-H loops, magnetic separation studies, magnetization
of components, magneto-optical measurements, and
superconducting material qualification. For continuous
operation fields can be in excess of 3T with a 25mm
pole gap or 2T with a 50mm pole gap. Intermittent
operation to 170A is possible with higher power
power supplies. This can be useful at higher gaps.
Alternatively, the 3474 can be integrated with a
very high performance Power Supply for spectrometry
applications.
If a high precision system is required, please go
the the High Precision
System page.
Please download our Minimum
Facilities Requirements paper for inportant
information regarding system installiation, site
set-up and materials required. |
|
| Specifications |
| Pole
gap |
Variable
from 0 to 160mm. |
| Pole
Face Diameter |
150mm
(250mm, 200mm 100mm, 75mm, 50mm,
and 25mm pole caps are also available). |
| Operating
Field |
±1.9T
at a pole gap of 51mm (2.0 inch) with ±140A excitation. |
| Field
Uniformity |
±350ppm
over a 40mm diameter disc in the
median plane. |
| Current
Stability |
0.1%
over 8 hours. (High stability power supply
available.) |
| Current
Control Resolution |
14
bit. |
| Field
Readout Resolution |
12
bit (0.2mT up to 1.2T field, 0.5mT up to 3.0T
field). |
| Computer
Control |
IEEE-488
interface with LabView. |
| Cooling |
Water,
15l/min (4 US gpm). |
| AC
Power (Power Supply) |
187-242V, 62A, 47-63Hz ac, 3 phase |
| AC
Power (Equipment Rack) |
115Vac,
single phase, 50/60Hz, 15A |
| |
| System
Components |
| 1A |
1 |
3474-140 |
H-frame
Electromagnet, 250mm, 140A coils |
26,440 |
| 1B |
1 |
17801713 |
Pole
pair, 150mm face diameter |
1,300 |
| 1C |
1 |
17801730 |
45°
Mounting Angle Pair |
540 |
| 1D |
1 |
11801800 |
Rolling
Base |
2,230 |
| 1E |
1 |
16900430 |
Cable,
Current and Interlock, 160A, 5m |
610 |
| 1F |
1 |
SGA100/150C-0AAA |
Power
Supply, 100V, 150A, unipolar.
Input: 187-242V, 62A, 47-63Hz ac, 3 phase. |
12,780 |
| 1G |
1 |
5970-160 |
Current
Reversing Switch, 160A |
4,340 |
| 1H |
1 |
16900420 |
Cable, Current and Interlock, SGA100/150 to 5970-160, 160A, 2m |
560 |
| 1I |
1 |
ADI-123-GUXCTS |
Analog
Device Interface, IEEE-488 controller, 14 bit resolution,
configured for SGA power supply. Installed
in to 5970-80 Reversing Switch. |
4,630 |
| Electromagnet
sub system: |
$53,430 |
| |
| 2A |
1 |
DTM-133-DG |
Digital
Teslameter, IEEE-488 Interface, 12-bit |
2,380 |
| 2B |
1 |
MPT-132-7s |
Hall
Probe, 4 range, 0.3T, 0.6T, 1.2T, 3.0T |
2,810 |
| 2C |
1 |
11901230 |
Probe
Holder, aluminum, transverse |
150 |
| 2D |
1 |
11901250 |
Probe
Mount, 4-way adjustable |
730 |
| Teslameter
sub system: |
$6,070 |
| |
| 3A |
1 |
RC-351930 |
Bench
height 19 inch rack |
2,600 |
| 3B |
1 |
17000025 |
Rack
Mounting Panel, 1 Teslameter |
110 |
| 3C |
1 |
17000058 |
Panel
Mount instrument Support Bracket |
70 |
| 3D |
1 |
CIF24-1m |
Cable,
IEEE-488, 1m |
160 |
| 3E |
1 |
CIF24-4m |
Cable,
IEEE-488, 4m |
200 |
| Rack
sub system: |
$3,140 |
| |
| 4A |
1 |
RMCS-P4 |
Rackmount
Computer System, Pentium 4.
| |
3U Rackmount Computer with rails, 2GB RAM, 250GB Hard Drive, DVD±R, Windows XP Pro, Keyboard & Optical Mouse, 17" LCD Monitor and 25' extension cables for keyboard, mouse & monitor. |
|
$2,240 |
| 4A |
1 |
778032-01 |
PCI-GPIB Interface for Windows 2000/XP/Vista |
800 |
| 4B |
1 |
LVMCTRL |
LabView
Magnet Control software |
1,070 |
| 4C |
1 |
776671-09 |
LabView for Windows, base package, 1Yr service |
1,800 |
| Computer
control sub system: |
$5,910 |
| |
| 5A |
1 |
MC300-A1-E1-
H2-J2 |
Water
Chiller, Water Cooled, Refrigerated
Re-circulating. Includes water temperature
and
pressure controls, filter, flow meter and
low
flow interlock. |
$11,670 |
| |
| 6A |
1 |
Installation |
Installation
& Training, up to 2 days at customers site
|
$5,230 |
| |
| Complete
Electromagnet System: |
$85,450 |
|
Specifications and pricing are subject to change
without notice.
GMW can provide a wide range of Electromagnet
Systems for laboratory and industrial applications.
Please contact us for more detailed information.
Last updated on: