Specifications
- 3474
|
| General |
| |
3474-140 |
3474-280 |
| Pole
Diameter |
250mm |
| Standard
Pole Caps |
25,
50, 75, 100, 150, 200, & 250mm |
| Pole
Gap |
0
to 160mm |
| Dimensions |
920mm
W x 636mm D x 864mm H |
| Weight |
1800kg
(3970 lbs) |
| Coils
|
Series
connected |
Series/parallel
connected |
| Resistance
(20°C) |
0.44W |
0.11W |
| Max
Resistance |
0.54W |
0.13W |
| Max
Power (air) |
40
Amps, 22 Volts (0.88kW) |
80
Amps, 10 Volts (0.88kW) |
| Max
Power (water) |
140
Amps, 76 Volts (10.6kW) |
280
Amps, 38 Volts (10.6kW) |
| Self
Inductance |
Approx
80mH |
| Water
Cooling |
15
liters/min, 2.0bar (4.0 US GPM, 30 psid) |
| Interlocks |
| Overtemperature |
Elmwood
3450G thermostat, mounted onto each cooling
plate, wired in series. Contacts
closed below 50°C |
| Water
Flow |
Johnson
Controls flow switch F61 KD mounted on outlet side
of water circuit. Contacts open with a flow
of less than 10 liters per minute. |
| Performance |
Fields
at maximum current of 140 Amps
 |
| |
Field
Uniformity
|
| |
| Drawings |
General
Assembly - 3474-140 & 3474-280
 |
Specifications are subject to change without