17000025,
17000026, & 17000027 - Rack Panels
Use a rack mounting panel to mount your DTM in to a 19"
standard rack. The part numbers above are for one, two,
or three DTMs, respectively.
|
17000058
- Instrument Support Bracket
An instrument support bracket is recommended for DTMs
mounted using the rack panels listed above. This item
is now included with all rack mounting DTMs, but 'twas
not always so. Order part number .
|
11901230
& 11901240 - Probe Holders
Probe mounting is a difficult problem for many users,
so we have developed a couple of probe holder options;
11901230 for MPT type probes to be mounted transversely,
and 11901240 for MPT probes mounted axially.
Additional Data:
11901230 Revision F Drawing pdf, 54Kb
11901240 Revision C Drawing pdf, 54Kb
|
|
5811,
9575, & 21000010 - Plug Packs
Several different power supply options are available:
The 5811 is the standard power adaptor that is
supplied in the U.S. Input: 120Vac, output: 10Vac, 1A
The 9575 is the standard power adaptor that is
supplied to Japan. Input: 100Vac, output: 10Vac, 1A
The 21000010 is a switch mode supply that we
recommend for use in electrically noisy environments.
Input 120Vac, output: 12Vdc, 1A.
|
11000036
- Ferrite Kit
A ferrite kit for noise suppression is also available.
This kit is applied to the power lead and probe cable
and will help keep transients out of the DTM. Order part
number:
|
|
CIF-24
- IEEE-488 Cables
IEEE-488 cables are also available here in 0.5, 1.0,
2.0, 4.0, and 8.0 meters long. The part numbers are:
CIF24-0.5m
CIF24-1m
CIF24-2m
CIF24-4m
CIF24-8m
|
11000039
- RS-232 Cables - Hard Wire
These are simple copper wire cables and are suitable for
use in labs or areas where noise pickup and transients
are not a concern. They come in standard 5 and 10 meter
lengths, with either male or female connectors. If noise,
transients, or high voltage gradients are to traversed,
use fiber optic cables.
RS-232C Cables:
11000039M-5m
11000039F-5m
11000039M-10m
11000039F-10m
|
BC04265-10
- Fiber Optic Cables
When the protection from noise or voltage transients are
required, or if the DTM is at a different voltage potential,
then fibre optic commuication cables are the way to go.
We offer several stock lengths, and custom lengths to
1000 meters are available.
Fiber Optic Cables:
BC04265-10-1m
BC04265-10-5m
BC04265-10-10m
BC04265-10-20m
BC04265-10-40m
|
FTR
- RS-232 to Fiber Optic Converters
Need to convert your RS-232 to fiber optic? We have just
the thing: The FTR, an RS-232 to fiber optic converter.
For more details about the FTR, please go here.
Last updated on:
16 August, 2007
|
|
|
|