| Absolute Maximum Ratings |
| Parameter |
Symbol |
Min |
Typ |
Max |
Unit |
Remarks |
| Storage Temperature |
TSTG |
-55 |
- |
100 |
°C |
|
| Ambient Temperature |
TA |
-40 |
- |
85 |
°C |
With Power |
| Supply Voltage |
VSUP |
-0.5 |
- |
+6.0 |
V |
|
Electro Static Discharge |
ESD |
2000 |
- |
- |
V |
Human Body Model ESD |
| Magnetic Field |
B |
- |
- |
1 |
Tesla |
|
| Recommended
Operating Conditions |
| Parameter |
Symbol |
Min |
Typ |
Max |
Unit |
Remarks |
| Supply
Voltage |
VSUP |
4.75 |
5.0 |
5.25 |
V |
|
| Supply
Current |
ISUP |
- |
28 |
35 |
mA |
|
Electrical Characteristics
Operating Conditions: VSUP = 5.0 V and TA= 25°C |
| Parameter |
360ASMF1 |
360ASMF2 |
360ASMF3 |
360ASMF4 |
Remarks |
| Full Scale Range |
0 to 360° |
0 to 30° |
0 to 90° |
0 to ±90° |
|
Analog Output Voltage Range (1)
When magnet is out of range |
0.5 to 4.5V ≤ 50mV |
2.5 ±2.0V ≤ 50mV |
|
| Analog Output Current |
±1mA max |
|
| Zero Angle Set |
Active High >4.75V prior to VSUP application |
Not to exceed 6V max.* |
| Zero Angle Set Output Level (1) |
0.5 ±0.01V |
2.5 ±0.01V |
|
| Response Time |
≈17ms |
|
| Resolution |
10bits |
|
| Accuracy |
± 1 deg |
±0.1 deg |
±0.25 deg |
±0.5 deg |
|
| Max horizontal magnetic field (2) |
50 mT (500G) |
|
| Min horizontal magnetic field (3) |
6 mT (60G) |
|
| Mechanical |
Dimensions Sensor
Cable |
21.8 x 3.4mm (0.86 x 0.040inch) length x height
460mm (18inch) length 24AWG Wire 7/32 Mil-W-768 |
| Weight |
6.6g (0.2 oz) |
| Case Material |
Fire Retardant Nylon 6 |
* Maintain for <100ms.
Note (1): Outputs are ratiometric to the supply voltage VSUP
Note (2): At surface of module
Note (3): Below 6 mT, Magnet “Out of Range” will be activated
|
| Drawings |