 Absolute Maximum Ratings
Parameter Symbol Min Typ Max Unit Remarks
  Supply Voltage Vsup 0 - 6.0 V   
  Operating Temperature T -40 - 125 °C  
  Storage Temperature Ts -40 - 150 °C  
 Recommended Operating Conditions
Parameter Symbol Min Typ Max Unit Remarks
  Supply Voltage Vsup 4.5 5 5.5 V  
  Output Current Iout -1 - 1 mA  
  Load Capacitance CL - - 1000 pF  
 Electrical Characteristics
 At T=-40°C to +150°C, Vsup=4.5V to 5.5V if not otherwise specified.
Parameter Symbol Min Typ Max Unit Conditions
  Supply Current Isup - 12  18 mA  
  Common Reference
  Output Voltage
1
VCommon Vsup/2
-20mV
Vsup/2 Vsup/2
+20mV
V Iout=0mA
  Bandwidth BW 10 15 18 kHz  
 Magnetic Input Conditions
 At T=-40°C to +150°C, Vsup=4.5V to 5.5V if not otherwise specified.
Parameter Symbol Min Typ Max Unit Conditions
  Maximum Field BMax - - 80 mT  
  Diameter of Magnetic
  Disc
Dfc - 0.2 - mm  
  Angular Speed w - - 100,000 rpm  
 Analog Output Characteristics2
 At T=-40°C to +150°C, Vsup=5.0V if not otherwise specified.
  Magnetic Sensitivity1 S 40 50 60 V/T  
  Magnetic Sensitivity
  Temperature Drift
1
S/ST -0.05 - +0.05 %°C Iout=0mA
T=-40 - +150°C
  Magnetic Sensitivity
  Missmatch (X-Y)
Sx/Sy - 0 2.0 % B=50mT
  Phase Matching Sx-Sy -0.3 0 +0.3 ° B=±50mT
  Offset Voltage Voff -10 0 +10 mV B=0,
Iout=0mA,
T=-20 - +80°C
  Offset Temperature
  Drift
Voff/T -0.05 0 +0.05 mV/°C B=0,
Iout=0mA
  Full Scale Magnetic
  Field Range
Bfs -45 - +45 mT S=50V/T
  Linear Magnetic Field
  Range
BL -40 - 40 mT S=50V/T
  Non Linearity NL    0.1 0.2 % B=±40mT
  Input Refered Magnetic
  Noise Spectrum
  Density (RMS)
Bnoise      750 nT/Hz  F=1Hz to 10kHz
 1. Ratio-metric (proportional to Vsup)
 2. When the analog pins Xout and Yout are used in differential mode. (i.e. Vx = x_out - co_out)
 


 Test Circuit:

Package: SOIC-8

  
Pin out:
 1) CO_OUT - Common Output
 2) PC - Programming Clock
1
 3) VDD (Vsup) - Positive Supply Voltage
 4) Y_OUT - Y Axis Analog Output
 5) X_OUT - X Axis Analog Output
 6) PD - Programming Data
1
 7) PV - Programming Voltage
1
 8) Gnd - Voltage Ground
 1. Used for factory programming of the 2SA-10.
Note
The preprogrammed data of the sensors are stored in an internal shift register. Strong electrostatic discharges may change the programmed parameters. To help protect the sensors from such disruption please follow the guidelines below when installing the sensors.

• Place a capacitor between VDD and GND in close proximity to the sensor.
• Use shielded, twisted pair cables whenever possible.
• Use a good power supply with adequate EMI protection.
• Connect the sensor programming voltage and clock inputs to VDD. Connect the programming data input to GND.

 Specifications subject to change without notice.