Senis 3MH6 High-Precision, Low-Noise Teslameter

Low Noise Teslameter with integrated Hall Probe incorporates a high accuracy magnetic field-to-analog-voltage transducer with a high-level, temperature compensated output signal for each of the three components of the measured magnetic flux density, Bx, By and Bz. A digital module is additionally applied to the analog transducer to form the digital Teslameter. Digital Teslameter provides the possibility of automatic data acquisition via a USB serial interface by a host computer. In this way, customers can easily integrate a measurement routine into their measurement system using its programming tools such as Basic, C, C++, Delphi, LabVIEW, etc.

The temperature measurement feature allows user to obtain current temperature values while monitoring the magnetic field.
The transducer consists of two modules:
1. Interchangeable Hall probe and Cable (Module H), and
2. Electronics (Module E).

The Low-Noise Digital Teslameter is a high accuracy temperature-stabilized instrument for the precise measurement of magnetic field.
Each Transducer is calibrated with the individual correction data for the connected probe, so the probe is replaceable.

Specifications

  • 4 selectable magnetic field measurement ranges: ± 100mT, 500mT, 2T, 20T (20T range is not calibrated)
  • Total measuring accuracy: 0.005% of measurement range
  • Magnetic resolution: 2ppm (24bit A/D conversion)
  • Frequency bandwidth: DC – 2.5kHz (-3dB)
  • Sampling rate (selectable): up to 7.5kSamples/sec
  • Selectable averaging time: 100ms – 133μs
  • Temperature stability: 20ppm/°C
  • External trigger: single shot / continuous; up to 4’000 Samples/sec
  • Measured data recording: data acquisition every 0.5sec – 60sec (up to 300 days)

Features

  • Teslameter with integrated 1-,2-, or 3-axis Hall Probes (Bx, By, Bz)
  • Measurement of DC & AC magnetic fields
  • Four selectable magnetic field ranges: 100mT, 500mT, 2T, 20T
  • In-factory calibrated up to +/-2T
  • High-field calibration up to +/-9T
  • Very high magnetic DC resolution: better than 1ppm
  • DC Accuracy along each axis: 0.01% (100ppm) up to +/-2T
  • Frequency bandwidth: DC – 2.5kHz (-3dB)
  • Numerical, graphical and statistical measurement visualization (Btot, Brms, Bx, By, Bz)
  • Measured Data Recording
  • External and internal triggers
  • USB Interface
  • Magnetic vector visualization
  • Units in gauss (G), tesla (T)
  • Suitable for probes of type C

Pricing

3MH6 3-Axis Digital Teslameter

Part No.DescriptionPriceIn Stock
3MH6

3-Axis Digitial Teslameter, 3-axis, 0.005% Digital Accuracy, +/-2T, DC-2.5kHz. Includes LabVIEW Driver

$29,010.00
COS50-A

Signal Output Cable, Unterminated on one end, 5.0m

$280.00
PHS-DL

Probe Holder, I3C, For C-Type Transducers

$1,110.00

Terms and Conditions

Terms and Conditions:

Prices above are for deliveries to USA, Canada, and Mexico only.
For deliveries in all other countries please contact Senis.
Prices are expressed in U.S. Dollars, FCA San Carlos, California.
Prices are subject to change without notice.
OEM discounts are available.

Payment:

Visa, MasterCard, Amex, Prepayment before shipment, or Net 30 days (subject to credit acceptance).