Metrolab Magnetic Field Camera, MFC2046
The Metrolab MFC2046 Magnetic Field Camera utilizes a proton NMR sensor Array to simultaneously measure up to 32 field points with better than 5ppm absolute accuracy and 0.1ppm relative accuracy in 0.5 to 2 seconds. For example, by using a semicircular Array with 32 field points rotated about the field axis in 32 angular steps, a 1024 point spherical map can be generated in about two minutes. The very high resolution and stability of the MFC also enable measurement of magnet stability and noise effects.
The MFC2046 takes advantage of common electronics with the PT2026 precision NMR teslameter. Now with a single instrument, one can use single point probes for applications such as decay measurements as well as probe arrays for mapping of MRI and NMR magnets. In addition to an array with fixed frequency probes, single single wide-band probe can be added. For example, a 32 point array with 500mm DSV at 127MHz could have a single probe placed to be at the ISO Center of the magnet that can measure from 1.2T to over 3T, following field ramp or field decay.
The MFC2046 probe arrays can have 10ppb (billion) field resolution and less than 1mm position resolution. New smaller coils allow 4mm spacing between probes, for mapping in a bore as small as 40mm. Whereas the previous Shim Camera’s were limited in field (7T) and number of points (32), the MFC2046 can measure to 25T (1GHz) and 255 points.
The MFC2046 is run via USB and includes LabVIEW software – Version 10 of MFCTool. In addition to the “classic” Metrolab file format, Version 10 introduces a powerful new XML-based format, as well as a plugin module to recover the measurement results in real time.
See Also:
Tech Support
- For the most recent version of MFCTools Software and MFC2046 Firmware, visit www.metrolab.com
- Occupational Magnetic Fields – Guidelines for DC Fields
- Magnetic Field Vector and Components
- MFC8246 Overview
Please contact Brian Richter (brian@gmw.com) for technical information on this product.
Accessories
3045-TC - Transit Case
The Transit Case offers superior protection from the dangers associated with the shipping of instruments. It provides space for a complete MFC system, including two probe arrays, and ample space is provided for user tooling as well.
MFC3039 - Mapping Fixture for Solenoid Magnets
Mapping is a breeze with the Rotating Probe Array holder. Designed for soleniod magnets, this fixture provides fast and accurate placement of the probe array within the magnet.
MFC3040 - Mapping Fixture for Vertical Magnets
Mapping is a breeze with the Rotating Probe Array holder. Designed for vertical magnets, this fixture provides fast and accurate placement of the probe array within the magnet.
Probe Normalization Jig
This jig provides a fast, easy way of locating the probe array during the probe normalization process.
Pricing
Calibration & Repair |
---|
For Calibration and Service, see Magnetic Field Calibration & Service. |
Quantity Discount Schedule: | |||||
---|---|---|---|---|---|
Quantity | 1 | 2 | 3 | 4 | 5 |
Discount | 0% | 2% | 3% | 4% | 5% |
Terms and Conditions
Terms and Conditions:
Prices above are for domestic deliveries to Canada, USA and Mexico only.
For deliveries in all other countries please contact Metrolab.
Prices are expressed in U.S. Dollars, FCA San Carlos, California.
Prices are subject to change without notice.
OEM discounts are available.
Payment:
Visa, MasterCard, Amex, Prepayment before shipment, or Net 30 days (subject to credit acceptance).
Delivery:
30 to 120 days.