Danisense Compact and OEM Current Transducers
The DaniSense DT, DC, DP and DX Series Current Transducers are based on a flux-gate zero flux detector with closed-loop operation to provide a signal output current accurately defined by the number of turns in the compensation winding. They provide higher accuracy for Power Analyzer measurements and improved performance for power amplifiers.
The DT, DC, DP and DX Series come in compact packages or unpackaged for use in tight spaces or integrated into OEM applications.
Features
- Very high absolute amplitude and phase accuracy from dc to over 1kHz
- Low signal output noise
- Low fluxgate switching noise on the pimary
- Enhanced electrostatic shielding to increase rejection of primary dV/dt coupling
- Increased operating temperature range
- Reduced mechanical dimensions
- Full-scale current ranges to 200Arms/±285A peak in a self-contained head small enough to fit in 1U chassis or unpackage for OEM integration
- Amplitude and Phase measurement to 300kHz included with each head
DaniSense Current Transducer Heads, DSSIU, Cables and Accessories are compatible with LEM IT Ultrastab Current Transducers.
Tech Support
- DaniSense Product Manual
- Principles of Zero Flux Current Transducers
- DW500UB-2V for Power Analyzer
- Flux-Gate
- Tech Note: “Wrap Around” or Distributed Primary Current Cable
- Accurate Power Conversion Measurements on High Power Motor Drives
- VAC Nanocrystalline Vitroperm Core EMC Products
- Product Name Guide
- Product Naming Letter
- How to Modify a DSSIU-6 from a Voltage Version to a Current Output Version
- How to Choose Danisense Current Transducers and System Interface Units
- Application Note: Replacing Shunts with Danisense Current Transducers for Calibration Systems
- Application Note: DCCT with Calibration Windings
- Application Note: Estimating Current Measurement Uncertainty when Utilizing Current Transducers
- Current Measurement for Electric Vehicle Charger Test – presentation by Ben Hartzell
- Outstanding DC Gain Accuracy and Stability Demonstrated in a 100A Measuring System
Clarke-Hess Communication Research Corp. - Precision Current Monitor System for the Power Supplies at SRRC
Yuan-Chen Chien et al, SRRC, Taiwan, Particle Accelerator Conference, 2001. - Large Scale Use of Solid State AC Power Sources for Automated Transformer Testing
Michael Orr, Pacific Power Source, Inc.; Alvin Kopp, High Voltage Test Engineering. - Solid-State AC Power Sources for Transformer Testing
Alvin Kopp, Michael Orr, Pacifica Power Source, Inc.
- Drawing – SP10381
- 3D Models, STEP files, Box.com link
Accessories
DaniSense Current Transducer (DCCT) Heads, DSSIU, Cables and Accessories are compatible with LEM IT Ultrastab Current Transducers.
The smallest power supply and interface unit from Danisense. Compatible with a wide range of current transducers.
- 1 Channel, +/-15V, 1.2 A System Interface Unit
- Universal mains input
- Banana measurement output
DSSIU-1 Transducer Interface Unit and Power Supply, single channel
DSSIU-6 Transducer Interface Unit and Power Supply, 6-channel
Fully configurable dedicated 6-channel system interface unit for Danisense DS series current transducers. Powers up to 6 x DS50 to DS2000 at the same time. Heads may be mixed (e.g. two DS2000IDLA and three DS200IDSA). Uses DB9 to DB9 cable for connection to transducer head (see cables below) and provides banana jack outputs for signal output.
Supports calibration windings and has 6 slots for optional voltage output modules VOM (1V or 10V), specified upon ordering.
Includes AC mains power cable. Other cables not included.
Additional Data:
Datasheet: DSSIU-6-1U Datasheet
DSSIU-4-1U Transducer Interface Unit and Power Supply, 4-channel
Provides Power and Signal connection for up to four Current Transducer heads. Heads may be mixed (e.g.: One DS2000ILLA and Three DS200ISSA Heads). DB9 connection to Transducer head and Banana Plug Jacks for Signal Output.
Includes AC Mains power cable. Other cables not included.
For Transducer Head to DSSIU-4-1U cable, see:
1411100001, 1411100002, 1411100003 ,1411100004 (descriptions below).
Additional Data:
Datasheet: DSSIU-4-1U Datasheet
Cables for Signal and Power, Calibration Winding Option
Signal, Power and Calibration Winding Cables |
||||
Part Number | Length | Termination A, Transducer Head |
Termination B | Cable Purpose |
---|---|---|---|---|
1411100001 | 2m | DB9M | DB9F | Signal, Power and Calibration Winding Cable. For use with DSSIU-4-1U or DSSIU-6-1U. |
1411100002 | 5m | DB9M | DB9F | Signal, Power and Calibration Winding Cable. For use with DSSIU-4-1U or DSSIU-6-1U. |
1411100003 | 10m | DB9M | DB9F | Signal, Power and Calibration Winding Cable. For use with DSSIU-4-1U or DSSIU-6-1U. |
1411100005 | 15m | DB9M | DB9F | Signal and Power Cable. For use with DSSIU-4 or DSSIU-6.1 |
1411100004 | 20m | DB9M | DB9F | Signal, Power and Calibration Winding Cable. For use with DSSIU-4 or DSSIU-6.1 |
1413100002 | 2m | DSSIU-6-1U-V: XLRm |
Banana Plugs | Current Signal Cable. For use with DSSIU-6-1U-V. |
1417100003 | 2m | DSSIU-6-1U-V: XLRm |
Banana Plugs | Voltage Signal Cable. For use with DSSIU-6-1U-V. |
SP10381 | 2m | DB9M | Unterminated | Signal and Power Cable.1 |
1416100001 | 10m | DB9M | DB9F | Signal and Power Cable. For use with DR5000 / DR10000 Transducer Systems |
1416100002 | 20m | DB9M | DB9F | Signal and Power Cable. For use with DR5000 / DR10000 Transducer Systems |
1416100007 | 25m | DB9M | DB9F | Signal and Power Cable. For use with DR5000 / DR10000 Transducer Systems |
1416100003 | 30m | DB9M | DB9F | Signal and Power Cable. For use with DR5000 / DR10000 Transducer Systems |
GMW-CT-BR-X.XX
The GMW-CT-BR-X.XX Burden Resistor Module generates a Voltage Monitor Signal when the current output from a closed-loop current transducer is connected to the current input terminals of a Power Analyzer or DaniSense Interface unit.
Additional Data:
Datasheet: GMW-CT-BR-X.XX Burden Resistor Module
16928-0000-0
The 16928-0000-0 Adapter Plug changes the pin-out matching from older LEM / Danfysik Current Transducers (IT 600-S and 866-600I) to newer LEM / Danfysik (IT 700-S or 867-700I) or DaniSense transducers.
Additional Data: 16928-0000-0_A_IST600S_Adaptor_Plug
V110
V110 Soft Magnetic Core, Toroidal, VITROPERM, 500F 63mm x 50mm x 25mm VAC Nanocrystalline Vitroperm Cores as Common Mode Choke
Additional Data:
VAC Brochure: VAC Nanocrystalline Vitroperm Core EMC Products
GMW Technical Presentation, Page 13, “Common Mode Choke”: Accurate Power Conversion Measurements on High Power Motor Drives
Pricing
DaniSense Current Transducer Heads, DSSIU, Cables and Accessories are compatible with LEM IT Ultrastab Current Transducers.
Compact and OEM Current Transducers
Part No. | Description | Price | In Stock |
---|---|---|---|
DT50ID | Current Transducer, 50Arms/±75A Peak, 1:500 Turns Ratio, 100mArms/±150mA Signal, DSUB Connector, Compact | $600.00 | |
DT100ID | Current Transducer, 100Arms/±150A Peak, 1:1000 Turns Ratio, 100mArms/±150mA Signal, DSUB Connector, Compact | $610.00 | |
DC200IF | Current Transducer, 200Arms/±300A DC, 1:1000 Turns Ratio, 200mArms/±300mA Signal, faston connector | $310.00 | |
DP50IP-B | Current Transducer, Programmable, 12.5/25/50Arms/±12.5/±25/±50A DC, 1:250/1:500/1:1000 Turns Ratio, PCB Mount | $305.00 | |
DT200ID | Current Transducer, 200Arms/±285A Peak, 1:1000 Turns Ratio, 200mArms/±285mA Signal, DSUB Connector, Compact | $620.00 | |
DX200IH-CP01 | Current Transducer, 200A DC, 1000:1 ratio, pcb and electronics, flat ribbon cable, DC-300kHz, offset 40ppm, linearity 6ppm, +/-15V | $330.00 |
DSSIU-1, DSSIU-4, DSSIU-6 Interface and Power Supply Units
Part No. | Description | Price | In Stock |
---|---|---|---|
DSSIU-1 | Current Transducer Interface, single-channel, DSUB to Transducer and Banana Plug Signal Connectors. Compatible with DT, DS, DQ, DN and DM series. | $540.00 | |
DSSIU-4-1U | Current Transducer Interface, four-channel, DSUB to Transducer and Banana Plug Signal Connectors | $1,370.00 | |
DSSIU-6-1U | Current Transducer Interface, six-channel, Calibration Current Connectors, Optional VOM (voltage output module) per channel (specify upon order), DSUB to Transducer and Banana Plug Signal Connectors | $1,730.00 | |
DSSIU-6-1U-V | Current Transducer Interface, six-channel, Calibration Current Connectors, DSUB to Transducer and XLR Mini Current or Voltage Output (depending on Configuration). If required: Specify VOM per channel. | $1,730.00 | |
VOM0100-1 | Voltage Output Module, 1V/100mA, 150mA max | $310.00 | |
VOM0100-10 | Voltage Output Module, 10V/100mA, 100mA max | $460.00 | |
VOM0300-1 | Voltage Output Module, 1V/300mA, 450mA max | $310.00 | |
VOM0300-10 | Voltage Output Module, 1V/300mA, 300mA max | $460.00 | |
VOM0400-1 | Voltage Output Module, 1V/400mA, 600mA max | $310.00 | |
VOM0400-10 | Voltage Output Module, 1V/400mA, 400mA max | $460.00 | |
VOM0667-10 | Voltage Output Module, 10V/667mA, 667A max | $460.00 | |
VOM0800-1 | Voltage Output Module, 1V/800mA, 1.2A max | $310.00 | |
VOM0800-10 | Voltage Output Module, 10V/800mA, 800mA max | $460.00 | |
VOM1333-1 | Voltage Output Module, 1V/1.33A, 2A max | $460.00 | |
VOM1333-10 | Voltage Output Module, 10V/1.33A, 1.33A max | $610.00 |
Accessories
Part No. | Description | Price | In Stock |
---|---|---|---|
S102CT-5R00 | Burden resistor, Metal Foil, 0.05%, 2ppm/C, 5Ω, recommended power <0.3W | $25.00 | |
S102CT-10R0 | Burden resistor, Metal Foil, 0.05%, 2ppm/C, 10Ω, recommended power <0.3W | $25.00 | |
S102CT-20R0 | Burden resistor, Metal Foil, 0.05%, 2ppm/C, 20Ω, recommended power <0.3W | $25.00 | |
S102CT-50R0 | Burden resistor, Metal Foil, 0.05%, 2ppm/C, 50Ω, recommended power <0.3W | $25.00 | |
S102CT-100R | Burden resistor, Metal Foil, 0.05%, 2ppm/C, 100Ω, recommended power <0.3W | $25.00 | |
S102CT-200R | Burden resistor, Metal Foil, 0.05%, 2ppm/C, 200Ω, recommended power <0.3W | $25.00 | |
HAA15-0.8-A+G | Power Supply, Open Frame, Linear, Dual, ±15V, 0.8A | $170.00 | |
HBB15-1.5-A+G | Power Supply, Open Frame, Linear, Dual, ±15V, 1.5A | $200.00 | |
HCC15-3-A+G | Power Supply, Open Frame, Linear, Dual, ±15V, 3.0A | $270.00 | |
16928-0000-0 | Adapter Plug, Danfysik / LEM to DaniSense | $90.00 | |
GMW-CT-BR-0.83 | Burden Resistor Module, .83 ohms, +/- .05%, 1500mA | $250.00 | |
GMW-CT-BR-1.0 | Burden Resistor Module, 1.0 ohms, +/- .05%, 1200mA | $250.00 | |
GMW-CT-BR-1.67 | Burden Resistor Module, 1.67 ohms, +/- .05%, 600mA | $250.00 | |
GMW-CT-BR-10.0 | Burden Resistor Module, 10.0 ohms, +/- .05%, 100mA | $250.00 | |
GMW-CT-BR-2.5 | Burden Resistor Module, 2.5 ohms, +/- .05%, 400mA | $250.00 | |
GMW-CT-BR-5.0 | Burden Resistor Module, 5.0 ohms, +/- .05%, 250mA | $250.00 | |
V110 | Soft Magnetic Core, Toroidal, VITROPERM, 500F 63mm x 50mm x 25mm | $80.00 |
DC Calibration
Note: Calibration on new product is discounted 50%.
Part No. | Description | Price | In Stock |
---|---|---|---|
CL-17025-1000A-DC | 17025 Accredited Calibration, Current Transducer, Full-scale Range between 0 and 1000Adc, https://gmw.com/quality/ | $500.00 | |
CL-17025-1000A-DC-ADD | Calibration of Additional Transducer | $250.00 | |
CL-17025-3000A-DC | 17025 Accredited Calibration, Current Transducer, Full-scale Range between 1001 and 3000Adc, https://gmw.com/quality/ | $800.00 | |
CL-17025-3000A-DC-ADD | Calibration of Additional Transducer | $400.00 | |
CL-17025-11000A-DC | 17025 Accredited Calibration, Current Transducer, Full-scale Range between 3001 and 11000Adc, https://gmw.com/quality/ | $1,500.00 | |
CL-17025-11000A-DC-ADD | Calibration of Additional Transducer | $750.00 |
AC Calibration
Note: Calibration on new product is discounted 50%.
Part No. | Description | Price | In Stock |
---|---|---|---|
CL-17025-1000A-AC | 17025 Accredited Calibration, Current Transducer, Full-scale Range between 0 and 1000Arms, 50-400Hz, https://gmw.com/quality/ | $500.00 | |
CL-17025-1000A-AC-ADD | Calibration of Additional Transducer | $250.00 | |
CL-17025-3000A-AC | 17025 Accredited Calibration, Current Transducer, Full-scale Range between 1001 and 3000Arms, 50-400Hz, https://gmw.com/quality/ | $800.00 | |
CL-17025-3000A-AC-ADD | Calibration of Additional Transducer | $400.00 | |
CL-17025-8000A-AC | 17025 Accredited Calibration, Current Transducer, Full-scale Range between 3001 and 8000Arms, 50-400Hz, https://gmw.com/quality/ | $1,500.00 | |
CL-17025-8000A-AC-ADD | Calibration of Additional Transducer | $750.00 |
Calibration and Repair
GMW provides application and engineering and calibration support for DaniSense Current Transducers.
For Calibration and Service of DaniSense Current Transducers see Calibration & Service
Quantity Discount Schedule: | ||
---|---|---|
Quantity | 1 – 9 | 10 – 24 |
Discount | 0% | 5% |
For multi-channel Current Transducer Systems, see Systems Pricing.
Terms and Conditions
Terms and Conditions:
Prices above are for domestic deliveries to Canada, USA and Mexico only.
Prices are expressed in U.S. Dollars, FCA San Carlos, California.
Prices are subject to change without notice.
Payment:
Visa, MasterCard, Amex, or Net 30 days (subject to credit acceptance).
Delivery:
From Stock to 60 Days